Subaru OBD-II 1996 & Newer models DTC P1096 – Tumble generator valve circuit #2 (open circuit)
DTC P1096 meaning on Subaru OBD-II 1996 & Newer models
DTC P1096 indicates an open circuit in the Tumble Generator Valve Circuit #2 on Subaru vehicles equipped with OBD-II systems from 1996 onwards.
Subaru OBD-II 1996 & Newer models DTC P1096 symptoms
Symptoms of DTC P1096 may include:
- Check Engine Light (MIL) illuminated
- Engine running rough or misfiring
- Reduced engine performance
Subaru OBD-II 1996 & Newer models DTC P1096 causes
Possible causes of DTC P1096 include:
- Open circuit in the Tumble Generator Valve Circuit #2
- Faulty Tumble Generator Valve
- Wiring or connector issues
Subaru OBD-II 1996 & Newer models DTC P1096 seriousness
While DTC P1096 may not always result in immediate drivability issues, it can lead to reduced engine performance and potential long-term damage if left unresolved.
How to diagnose DTC P1096 on Subaru OBD-II 1996 & Newer models
To diagnose DTC P1096, a mechanic should:
- Use an OBD-II scanner to retrieve the fault code
- Inspect the Tumble Generator Valve Circuit #2 for any visible damage or loose connections
- Test the Tumble Generator Valve for proper operation
- Check the wiring harness and connectors for continuity and proper voltage
How to fix DTC P1096 on Subaru OBD-II 1996 & Newer models
To fix DTC P1096, the following steps may be taken:
- Repair any damaged wiring or connectors in the Tumble Generator Valve Circuit #2
- Replace the faulty Tumble Generator Valve if necessary
- Clear the fault code using an OBD-II scanner after repairs are completed
How to erase DTC P1096 on Subaru OBD-II 1996 & Newer models
To erase DTC P1096, follow these steps:
- Connect an OBD-II scanner to the vehicle’s diagnostic port
- Select the option to clear fault codes from the scanner menu
- Confirm the action and wait for the scanner to clear the code